ASNT NDT LEVEL III PROGRAM

The ASNT NDT Level III program provides third-party certification for nondestructive testing (NDT) personnel whose specific jobs require knowledge of the technical principles underlying the non-destructive tests they perform witness, monitor, or evaluate. The program provides a system for ASNT NDT Level III certification in NDT in accordance with Recommended Practice No. SNT-TC-1A.

Certification under this program results in the issuance of an ASNT certificate and wallet card attesting to the fact that the certificate holder has met the published guidelines for the Basic and Method examinations as detailed in Recommended Practice No. SNT-TC-1A.

ASNT Level III Preparatory course

The ASNT NDT Level-III preparatory courses are designed to help the students to expand their knowledge of important concepts in each NDT topic. The courses are available both online and classroom training at our facility.

ASNT Level III Basic Exam

The ASNT level III preparatory course is designed to prepare each exam candidate for exam success. Our online program covers in detail the three main components:

  •  Qualification and certification according to the ASNT, SNT-TC-1A, and ANSI/ASNT CP- 189, latest edition.
  •  Materials, fabrication, and product technology
  •  Eleven(11) NDT methods

ASNT LEVEL III Method Examinations:

ASNT Level III preparatory training will cover the syllabus outlined in ANSI/ASNT CP-105 where applicable.

The NDT methods Preparatory courses available at present are:

  •  Magnetic Particle Testing – MT
  •  Penetrant Testing – PT
  •  Visual testing – VT
  •  Ultrasonic Testing – UT
  •  Radiographic Testing – RT
  •  Electromagnetic Testing –ET

Our online ASNT Level III Exam preparatory courses save students time and money on travel, food, and lodging expenses and allow them to study at their own pace, focus on the areas they need most and clear the exams at the first attempt.

Our courses are well structured with multiple practice question sessions.

WHO SHOULD ATTEND:

The ASNT Level III courses are designed for those who are currently Level II and are looking to become an NDT Level III or to maintain their Level III status.

ASNTReferenced Documents for Examination Preparations

 https://www.asnt.org/MajorSiteSections/Certification/ASNT_NDT_Level_III/Examinations.aspx


Topical Outline(BASIC)

This examination is 4 hrs in length, having 135 questions of equal value.

1. Administration of NDT personnel certification programs

  •  SNT-TC-1A, 2016 edition
  •  ASNT CP-189, 2016 edition

2. General familiarity with other NDT methods

  •  Radiography (safety, X-ray, and isotope methods)
  •  Neutron radiography
  •  Ultrasonic testing
  •  Eddy current and flux leakage testing
  •  Magnetic particle testing
  •  Leak testing
  •  Acoustic emission testing
  •  Visual testing
  •  Thermal/infrared

3. Materials, fabrication, and production technology

  •  Properties of materials, origin of discontinuities, and failure modes
  •  Materials processing (casting, welding, forging, brazing, soldering, machining,heat treatment, surface treatment, adhesive bonding, etc.)
  •  Dimensional metrology

References

The number in parentheses following each reference is the ASNT catalog number.

 ASNT Level III Study Guide: Basic Revision, Third Edition (2251)
 SNT-TC-1A (2016 edition) (2072)
 Supplement to Recommended Practice No. SNT-TC-1A: Complete Set of Supplements, Plus Recommended Practice No. SNT-TC-1A (2011 edition) (2192)
 Materials and Processes for NDT Technology, Second Edition (2250)
 ANSI/ASNT CP-189 (2016 edition) (2509)
 NDT Handbook, Third Edition: Volume 10, NDT Overview (0140)
 ASM Handbook Vol. 17, NDE and QC (0105)


About Magnetic Particle Testing (MT)

Magnetic Particle Testing uses one or more magnetic fields to locate surface and near-surface discontinuities in ferromagnetic materials. The magnetic field can be applied with a permanent magnet or an electromagnet. When using an electromagnet, the field is present only when the current is being applied. When the magnetic field encounters a discontinuity transverse to the direction of the magnetic field, the flux lines produce a magnetic flux leakage field of their own.

Topical Outline(MPT)

This examination is 2 hrs in length, having 90 questions of equal value

  •  Principles/Theory
  •  Principles of magnets and magnetic fields
  •  Characteristics of magnetic fields
  •  Equipment/Materials
  •  Magnetic particle test equipment
  •  Inspection materials
  •  Technique/Calibrations
  •  Magnetization by means if electric current
  •  Selecting the proper method of magnetization
  •  Demagnetization
  •  Interpretation/Evaluation
  •  Procedures
  •  Safety and Health

References

The number in parentheses following each reference is the ASNT catalog number.

 NDT Handbook: Third Edition, Volume 8, Magnetic Testing (0148)
 Level III Study Guide: Magnetic Particle Testing, Second Edition (2253)
 Supplement to Recommended Practice No. SNT-TC-1A (Q&A) Book — Magnetic Particle Method, Second Edition (2027)


About Liquid Penetrant Testing

Liquid penetrant testing is capable of revealing only those discontinuities which are open to the surface. Liquid Penetrant is an improvement over visual inspection. Penetrant testing increases the sensitivity of flaw detection by highlighting a discontinuity for easier visual detection. The discontinuity is magnified in size by an indication produced on the surface being examined as a direct result of the test. Liquid Penetrant Testing (PT) is the most widely used NDT inspection method. It is very inexpensive, does not require an extraordinary amount of training, and is more sensitive than a visual inspection alone.

Topical Outline(PT)

This examination is 2 hrs in length, having 90 questions of equal value.

  •  Principles/Theory
  •  Principles of liquid penetrant process
  •  Theory
  •  Proper selection of PT as method of choice
  •  Liquid penetrant processing
  •  Equipment/Materials
  •  Liquid penetrant test units
  •  Methods of measurementnt
  •  Lighting for liquid penetrant testing
  •  Materials for liquid penetrant testing
  •  Testing and maintenance of materials
  •  Interpretation/Evaluation
  •  General
  •  Factor affecting indications
  •  Indications from discontinuities
  •  Relevant and Nonrelevant indications
  •  Procedures
  •  Liquid penetrant testing procedures, codes, standards and specifications
  •  Safety and Health
  •  Toxicity
  •  Flammability
  •  Electrical hazards
  •  Personnel protective equipment
  •  Right to know (MSDS)
  •  Disposal of used materials

References

The number in parentheses following each reference is the ASNT catalog number.

 Level III Study Guide: Liquid Penetrant Testing Method (PT), Second Edition (2255)
 NDT Handbook, Fourth Edition: Volume 1, Liquid Penetrant Tests (0142, 0142CD, 0142WCD)
 Supplement to Recommended Practice No. SNT-TC-1A (Q&A Book) - Liquid Penetrant Testing Method, Revised Edition (2029)


About Radiographic Testing (RT)

Industrial radiography involves exposing a test object to penetrating radiation so that the radiation passes through the object being inspected and a recording medium placed against the opposite side of that object. For thinner or less dense materials such as aluminum, electrically generated x-radiation (X-rays) are commonly used, and for thicker or denser materials, gamma radiation is generally used.

Topical Outline(RT)

This examination is 4 hrs in length, having 135 questions of equal value

  •  Principles/Theory
  •  Equipment/Materials
  •  Electrically generated sources
  •  Particulate radiation sources
  •  Radiation detectors
  •  Techniques/Calibration
  •  Imaging considerations
  •  Film processing
  •  Viewing of radiographs
  •  Judging radiographic quality
  •  Exposure calculations
  •  Radiographic techniques
  •  Interpretation and Evaluation
  •  Procedures
  •  Safety and Health
  •  Exposure hazards
  •  Methods of controlling radiation exposure
  •  Operational and emergency procedures
  •  Dosimetry and Film Badges

References

The number in parentheses following each reference is the ASNT catalog number.

 Level III Study Guide: Liquid Penetrant Testing Method (PT), Second Edition (2255)
 NDT Handbook, Fourth Edition: Volume 1, Liquid Penetrant Tests (0142, 0142CD, 0142WCD)
 Supplement to Recommended Practice No. SNT-TC-1A (Q&A Book) - Radiographic Testing Method (2026)
 Working Safety in Radiography (0232)


About Ultrasonic Testing (UT)

Ultrasonic testing uses the same principle as is used in naval SONAR and fish finders. Ultra-high frequency sound is introduced into the part being inspected and if the sound hits a material with a different acoustic impedance (density and acoustic velocity), some of the sound will reflect back to the sending unit and can be presented on a visual display. By knowing the speed of the sound through the part (the acoustic velocity) and the time required for the sound to return to the sending unit, the distance to the reflector (the indication with the different acoustic impedance) can be determined.

Topical Outline

This examination is 4 hrs in length, having 135 questions of equal value

  •  Principles/Theory
  •  Equipment/Materials
  •  Techniques / Calibration
  •  Contact
  •  Immersion
  •  Comparison of contact and immersion methods
  •  Remote monitoring
  •  Calibration (electronic and functional)
  •  Interpretation/Evaluations
  •  Evaluation of base metal product forms
  •  Evaluation of weldments
  •  Evaluation of bonded structures
  •  Variables affecting test results
  •  Evaluation (general)
  •  Procedures
  •  Specific applications
  •  Codes/Standards/Specifications
  •  Safety and Health

References

The number in parentheses following each reference is the ASNT catalog number.

 Level III Study Guide: Ultrasonic Testing Method (UT), Second Edition (2261)
 NDT Handbook Third Edition: Volume 7, Ultrasonic Testing (UT) (0147)
 Ultrasonics: Fundamentals, Technology, Applications, Third Edition (0341)
 ASM Handbook, Volume 17, NDE and QC (0105)